Getting the right HVAC solution for Healthcare and Patient rooms is more important than ever after the recent Pandemic highlighted the importance in selecting the right HVAC system that reduces the risk of Cross-Contamination, lowers energy consumption, and improves Indoor Air Quality (IAQ) and Thermal Comfort for Patients and other building occupants Wellbeing.
Frenger Systems® have a wealth of experience of 'Healthcare' applications stemming back some 80 years when Frenger Troughton Young pioneered the supply and installation of Frenger Heated Ceilings to most, if not all hospitals in the United Kingdom.
Cooling / Heating for Hospitals and other Healthcare applications need to be designed as a bespoke cooling solution to fit around the facilities requirements, whilst not only prioritising the health and Wellbeing of patients and other building occupants, but also to provide an energy efficient (Net Zero) and deliverable solution.
Chilled beams are a tried and tested technology predominately used in 'owner occupied' buildings or buildings where the person paying the energy and/or maintenance bills are influential in the HVAC equipment selection / solution. One such sector is 'Healthcare'.
Frenger® utilise their Active Chilled Beam technology with shallow depth constructed units specifically designed for 'Healthcare' applications in mind and have a 'drop down' heat exchanger for easy cleaning of all 4 sides of the heat exchanger from the room side and no cross-contamination of recirculated room air. Find out more about Active Chilled Beams for Healthcare and Patient room applications by clicking the 'Download' button below.
Important aspects to consider when designing the system for Healthcare applications:
- Reducing the Risk of Contamination
- Excellent Thermal Comfort
- Excellent Indoor Air Quality (IAQ)
- Excellent Energy Saving (Net-Zero / Carbon Reduction)
- Quiet Operation
- Minimal Maintenance
Healthcare Chilled Beams
Featuring a closed-back design and a 'drop down' heat exchanger, Frenger's Healthcare variant of their Eco Active Chilled Beam is an ideal solution for Hospitals and other Healthcare applications.
Learn MoreFrenger's Halo Active Chilled Beam utilises a true 360° discharge characteristic with concealed air discharge vanes, which when compared to traditional 2-way or 4-way discharge pattern by others, the Halo can deliver a reduction in air velocities of up to 35%.
Learn MoreFrenger's one-way discharge Ultima Healthcare Chilled Beams contains a number of their patented performance enhancing features as well as a drop-down heat exchanger for periodic cleaning and maintenance associated with Healthcare applications.
Learn MoreIf you require any further information, or have a project to discuss, please contact us on 61 2 9006 1147 or sales@frenger.com.au as our technical team are here to assist.